| Date: | Wed, 10 Jan 2001 09:08:41 -0500 |
| Reply-To: | CICS List <CICS-L@LISTSERV.UGA.EDU> |
| Sender: | CICS List <CICS-L@LISTSERV.UGA.EDU> |
| From: | "Moore, Ken x23826" <MooreK@BIS.ADP.COM> |
| Subject: | Re: Abend 4094 - LE Problem when application Terminates - Urgent |
| Content-Type: | multipart/alternative;
|
|---|
The only time I've seen the 4094 is when I had a problem with my CESE TDQ.
When the program ends, if RPTSTG or RPTOPTS is on, or the program abends and
LE gets an error trying to write diagnostic information to CESE, it will
produce this message.
Check to make sure CESE is defined and check to make sure that CEEMSG has
the correct LRECL and DCB information (from the LE installation guide).
Ken Moore
ADP Brokerage Services Group
-----Original Message-----
From: P Karthikeyen [mailto:pkarthik@CHENNAI.TCS.CO.IN]
Sent: Tuesday, January 09, 2001 11:02 PM
To: CICS-L@LISTSERV.UGA.EDU
Subject: Abend 4094 - LE Problem when application Terminates - Urgent
Hi all,
We have a Strange Problem in one of our Web based application. The
mirror
Transaction gets abended with 4094 & the log
has the following information: CEE1000S LE/370 INTERNAL ABEND. ABCODE = 4094
REASON = 00000014 . This occurs when the control returns to CICS.
We checked the book manager for the following abcode & reason code and the
messgae is : Program management could not properly terminate.
We cheked our application but we are unable to find out whether it is an
application or system problem.We also use CODE/370 for CICS Debugging.
Could any one in the list help us to find out the problem? This is a very
urgent
problem since lot of work has been halted due to this.
Thanks in advance,
Karthik
[text/html]
|